Skip to content
get an extra 10% off - or more! Discounts Applied at checkout
by Wilkins
SKU 114-975XL2U

Zurn 114-975XL2U 1-1/4" Lead-Free Reduced Pressure Principle Backflow Preventer

Zurn 114-975XL2U 1-1/4" Lead-Free Reduced Pressure Principle Backflow Preventer

by Wilkins
SKU 114-975XL2U
Original price $2,890.00
Save $1,589.50 (55%)
Original price $2,890.00 - Original price $2,890.00
Original price $2,890.00
Current price $ 1,30050
$1,300.50 - $1,300.50
Current price $1,30050
The Zurn 114-975XL2U Reduced Pressure Principle Backflow Preventer is designed to safeguard potable water systems from contamination caused by backpressure or backsiphonage. This lead-free assembly is ideal for high-hazard installations in commercial and industrial settings, providing superior protection for drinking water supplies. Constructed from durable bronze, this backflow preventer features...

In Stock, Usually Ships within 1-2 Business days

In Stock, Usually Ships within 1-2 Business days

Free Easy Return Online

Return this item within 30 days of purchase. Read Return Policy

Free Easy Return Online

Return this item within 30 days of purchase. Read Return Policy

Translation missing: en.accessibility.collapsible_content_title

Product Details

The Zurn 114-975XL2U Reduced Pressure Principle Backflow Preventer is designed to safeguard potable water systems from contamination caused by backpressure or backsiphonage. This lead-free assembly is ideal for high-hazard installations in commercial and industrial settings, providing superior protection for drinking water supplies.

Constructed from durable bronze, this backflow preventer features a wye-pattern design that allows for separate access to the relief valve and check valves, simplifying maintenance and reducing downtime. The compact design makes it easy to install, even in tight spaces. Additionally, the valve includes full-port union ball valves for quick shutoff and easy serviceability.

Key Features:

  • Lead-Free Construction: Complies with NSF/ANSI 61 standards for safe use in potable water systems.
  • Wye Pattern Design: Offers easy access to internal components, reducing labor costs for repairs and maintenance.
  • Durable Materials: Built from lead-free bronze and stainless steel, ensuring longevity and resistance to corrosion.
  • Union Ball Valves: Full-port valves for easier installation and service.
  • Compliance: ASSE® Listed 1013, CSA® Certified, AWWA Compliant, and approved by the University of Southern California's Foundation for Cross-Connection Control.

Specifications:

  • Size: 1-1/4" FNPT
  • Maximum Pressure: 175 PSI
  • Temperature Range: Up to 180°F
  • Certifications: NSF/ANSI 61, ASSE® Listed 1013, CSA® Certified

FAQ

1. What is the Zurn 975XL2U used for?

The Zurn 975XL2U is a reduced pressure principle backflow preventer designed to protect potable water systems from contamination due to backsiphonage or backpressure. It is typically used in high health hazard applications, such as commercial or industrial water supply systems.

2. What are the key features of the Zurn 975XL2U?

  • Lead-free cast bronze construction
  • Wye pattern design for easy access to internal components, reducing maintenance time and costs
  • Maximum working pressure of 175 PSI
  • Maximum working temperature of 180°F
  • Compliant with NSF/ANSI/CAN 61 standards
  • ASSE® Listed 1013, IAPMO® Listed, and CSA® Certified

3. In what sizes is the Zurn 975XL2U available?

The Zurn 975XL2U is available in sizes ranging from 3/4" to 2", making it suitable for a variety of water line sizes.

4. How does the Zurn 975XL2U work to prevent backflow?

This device uses a reduced pressure zone assembly to prevent contaminated water from flowing back into the potable water supply. It consists of two check valves with an intermediate relief valve that opens if the pressure between the two valves becomes too high, ensuring the system remains protected.

5. What makes the Zurn 975XL2U unique compared to other backflow preventers?

The Zurn 975XL2U features a wye pattern design, which offers separate access to each check valve and the relief valve. This layout simplifies maintenance and repair, reducing labor costs and system downtime. Additionally, its short lay length makes it easier to install or replace.

6. What installation considerations should I be aware of for the Zurn 975XL2U?

The 975XL2U must be installed at a minimum of 12 inches and a maximum of 30 inches above the floor or ground, and adequate drainage should be provided to prevent submersion. Proper side clearance is necessary for maintenance and testing.

7. Is the Zurn 975XL2U compliant with safety and plumbing standards?

Yes, the Zurn 975XL2U complies with several standards, including:

  • ASSE® 1013 Listed
  • NSF/ANSI/CAN 61 Certified
  • AWWA Compliant C511

8. Does the Zurn 975XL2U come with any additional accessories?

Optional accessories for the 975XL2U include air gaps, repair kits, and thermal expansion tanks, all of which can help enhance the device’s performance and lifespan.

These FAQs cover essential details about the product's use, maintenance, and compliance standards, providing valuable insights for potential buyers or installers.

Free Shipping

Free shipping on orders of $25 or more

SPEEDY DELIVERY

Get your products fast with our lightning-fast shipping

UNBEATABLE PRICES

Experience top-quality products at low prices

TOP RATED SUPPORT

Experience our blazing-fast customer service

Free Shipping

Free shipping on orders of $25 or more

SPEEDY DELIVERY

Get your products fast with our lightning-fast shipping

UNBEATABLE PRICES

Experience top-quality products at low prices

TOP RATED SUPPORT

Experience our blazing-fast customer service