The Zurn 114-950XLT2 is a lead-free double check valve backflow preventer designed for use in low-hazard potable water systems. Its top-access design allows for easy maintenance of internal components, making it ideal for installations in standard meter boxes or below-grade valve boxes. Constructed from cast bronze, this...

In Stock, Usually Ships within 1-2 Business days

In Stock, Usually Ships within 1-2 Business days

Free Easy Return Online

Return this item within 30 days of purchase. Read Return Policy

Free Easy Return Online

Return this item within 30 days of purchase. Read Return Policy

Translation missing: en.accessibility.collapsible_content_title

Product Details

The Zurn 114-950XLT2 is a lead-free double check valve backflow preventer designed for use in low-hazard potable water systems. Its top-access design allows for easy maintenance of internal components, making it ideal for installations in standard meter boxes or below-grade valve boxes. Constructed from cast bronze, this valve assembly is durable and corrosion-resistant, ensuring reliable performance in commercial applications.

The 114-950XLT2 backflow preventer is equipped with a clog-resistant test cock plug and includes corrosion-resistant stainless steel springs and fasteners. It complies with federal low-lead requirements, making it safe for potable water applications. This assembly protects against both backsiphonage and backpressure, making it essential for safeguarding potable water lines.

Key Features:

  • Lead-Free Design: Meets low-lead requirements for safe use in potable water systems.
  • Top Access for Easy Maintenance: Allows for quick servicing without removing the device from the line.
  • Durable Construction: Cast bronze body with stainless steel springs and fasteners.
  • Clog-Resistant Test Cock: Designed to prevent fouling from insects, dirt, and debris.
  • Application: Suitable for commercial and industrial potable water systems.

Specifications:

  • Size: 1-1/4"
  • Material: Lead-free cast bronze
  • Max Pressure: 175 PSI
  • Max Temperature: 180°F
  • Hydrostatic Test Pressure: 350 PSI
  • Connection Type: Female threaded
  • Certifications: ASSE 1015, NSF/ANSI 61, AWWA C510 compliant

FAQ

1. What is the Zurn 114-950XLT2 used for?

The Zurn 114-950XLT2 is a double check valve assembly designed to prevent backflow in potable water systems, protecting against both backsiphonage and backpressure. It is commonly used in commercial and industrial applications where water supply contamination needs to be prevented.

2. What are the key features of the Zurn 114-950XLT2?

  • Lead-free cast bronze construction
  • Top access for easy maintenance
  • Replaceable seats and silicone seal rings
  • Approved for low-lead applications
  • Maximum working pressure: 175 PSI
  • Maximum working temperature: 180°F
  • Hydrostatic test pressure: 350 PSI
  • Certified to NSF/ANSI 61 standards

3. In what sizes is the Zurn 114-950XLT2 available?

The Zurn 950XLT2 series is available in sizes ranging from 3/4" to 2". The 114-950XLT2 specifically refers to the 1-1/4" size model.

4. How does the Zurn 114-950XLT2 prevent backflow?

This device uses a double check valve system, where two independent valves work to prevent water from flowing backward into the main supply, thus protecting potable water from contaminants.

5. What are the installation requirements for the Zurn 114-950XLT2?

The assembly must be installed in accordance with local codes and the manufacturer’s instructions. It is typically installed 12" to 30" above ground level, with sufficient clearance for testing and maintenance. It can also be installed in meter boxes for below-ground setups.

6. Is the Zurn 114-950XLT2 compliant with safety and plumbing standards?

Yes, it complies with several standards, including:

  • ASSE Listed 1015
  • IAPMO Listed
  • CSA Certified
  • AWWA Compliant C510
  • NSF/ANSI 61 Certified for low-lead applications

7. Does the Zurn 114-950XLT2 require any additional accessories?

Optional accessories include the Model SXL lead-free strainer and a repair kit for rubber components. These accessories can enhance the functionality and lifespan of the assembly.

8. What maintenance does the Zurn 114-950XLT2 require?

Routine maintenance includes checking the valve seals and replacing the silicone rings as needed. The top access design makes it easy to perform repairs without removing the device from the pipeline.

These FAQs address common concerns about the product and can be adjusted as needed depending on specific customer questions or industry standards.

Free Shipping

Free shipping on orders of $25 or more

SPEEDY DELIVERY

Get your products fast with our lightning-fast shipping

UNBEATABLE PRICES

Experience top-quality products at low prices

TOP RATED SUPPORT

Experience our blazing-fast customer service

Free Shipping

Free shipping on orders of $25 or more

SPEEDY DELIVERY

Get your products fast with our lightning-fast shipping

UNBEATABLE PRICES

Experience top-quality products at low prices

TOP RATED SUPPORT

Experience our blazing-fast customer service

Compare products

{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}

Select first item to compare

Select second item to compare

Select third item to compare

Compare